MedicineOrthopaedic SurgeryOrthopedic SurgeryJoint Replacement SurgeryOrthopaedic BiomaterialsOrthopedicsCeramic BiomaterialsComplications Of Implant ProsthesesHip ArthroplastyJoint Replacement MaterialsSocket DesignAlumina ImplantsCeramic BearingsCeramic ImplantsImplant Migration AnalysisOrthopedic ImplantsTotal Hip Arthroplasty BearingsWear Particle AnalysisWear Particles
The current authors review clinical and retrieval experiences with hemispheric monolithic alumina ceramic sockets (Group 1), implanted between 1976 and 1979, and similar modular titanium sockets with alumina ceramic inlays (Group 2), implanted between 1990 and 1995. Both cementless sockets articulated with alumina ceramic femoral ball heads for total hip joint replacements. Clinical followup of patients with hemispheric monolithic alumina ceramic sockets (Group 1, 138 sockets) resulted in a total failure rate of 19.6% after 5 to 20 years. Radiologic analysis of eight stable sockets showed migration of 0.2 mm to 2.89 mm, but in four sockets at risk for late aseptic failure after an average followup of 12.5 years as much as 13.4 mm of migration was seen. Histologic evaluation revealed pseudosynovial membranes as thick as 1 mm with fine birefringent wear particles within mononuclear macrophages around two stable retrieved sockets. The membranes around four loose sockets were 6 to 10 mm thick and also heavily loaded with larger alumina wear particles. After 7 years followup clinical analysis of patients with modular titanium sockets with alumina ceramic inlays (Group 2, 30 sockets) resulted in four revisions, compared with one revision of 50 identical sockets (control group) with polyethylene instead of alumina ceramic inlays. Wear particle analyses in scanning electron microscopy showed significantly more particles (x 10(9) +/- standard deviation/g dry tissue) from the control group (4.26+/-6.38), compared with alumina ceramic bearings of Group 1 (0.70+/-0.79), and of Group 2 (1.62+/-2.13). The alumina particle sizes ranged between 0.13 and 78.38 microm. The mean annual linear wear of 38.8 microm was calculated for the bearings in Group 1, and of 26.94 microm for bearings in Group 2. These results support the good tribologic and biologic performance of alumina ceramic bearings for total hip arthroplasty.
11
Structural and cellular assessment of bone quality of proximal femur
Lawrence D. Dorr, Marie–Claude Faugere, Audley M. Mackel et al. · Bone · 1993 · 908 citations
Long-term results of uncemented alumina acetabular implants
M. Boehler, K. Knahr, H. Plenk et al. · Journal of Bone and Joint Surgery - British Volume · 1994 · 151 citations