Publication | Open Access
Storage Ring Measurement of the C<scp>iv</scp>Recombination Rate Coefficient
110
Citations
33
References
2001
Year
The low energy C IV dielectronic recombination (DR) rate coefficient associated with 2s→2p ∆n = 0 excitations of this lithiumlike ion has been measured with high energy-resolution at the heavy-ion storage-ring tsr of the Max-Planck-Institut für Kernphysik in Heidelberg, Germany. The experimental procedure and especially the experimental detection probabilities for the high Rydberg states produced by the recombination of this ion are discussed in detail. From the experimental data a Maxwellian plasma rate coefficient is derived with ±15 % systematic uncertainty and parameterized for ready use in plasma modeling codes. Our experimental result especially benchmarks the plasma rate coefficient below 10 4 K where DR occurs predominantly via C III(1s 2 2p4l) intermediate states and where existing theories differ by orders of magnitude. Furthermore, we find that the total dielectronic and radiative C IV recombination can be represented by the incoherent sum of our DR rate coefficient and the RR rate coefficient of Pequignot et al. (1991, Astron. Astrophys., 251, 680). Subject headings: atomic data — atomic processes — recombination — X-rays: general 1.
| Year | Citations | |
|---|---|---|
Page 1