Journal of Bridge Engineering · 2007 · 30 citations · 1 references
EngineeringCivil EngineeringBridge EngineeringFinite Element AnalysisStructural EngineeringBending Of BeamsBridge ConstructionBridge DesignBridge LoadsBridge Structural AnalysisStructural Response AnalysisBridge Load AnalysisConnectorsLive Load AnalysisLoad DistributionLoad Distribution In Bridge DecksParametric StudiesShear BehaviorShear Stress Forces
This paper summarizes field-testing of eight decked bulb-tee girder bridges as well as development of three-dimensional finite-element (FE) models. Using the calibrated 3D FE models, parametric studies have been performed to study the effect of shear connectors and intermediate diaphragms on live-load distribution and connector forces. It was found that: (1) in all cases studied, the live- load distribution factor (DF) for a single-lane loaded bridge was smaller than one for a double-lane loaded bridge; (2) connector forces caused by wheel loads were not uniform along the longitudinal joint—adding intermediate diaphragms tended to reduce the difference among horizontal shear forces in connectors; (3) the maximum horizontal shear force increased with the increase of the connector spacing—intermediate diaphragms reduced the maximum horizontal shear force in connectors; (4) the maximum vertical shear force and in-plane normal tensile force in connectors do not necessarily increase with the increase of the connector spacing; and (5) the summation of connector forces in each direction along the longitudinal joint remained constant irrespective of the number of connectors in the joint.
1