PharmacyPharmacologyDrug DeliveryPulmonary Drug DeliveryPulmonologyAerosolized Medication DeliveryBronchodilator TherapyInhalation Drug DeliveryInhalation TherapyLung DepositionMetered-dose InhalersLung Deposition MeasurementMetered-dose Inhaler DepositionMetered-dose Inhaler UseOpen-label TrialsParticle DepositionPilot Study DesignPressurized Metered Dose InhalersSpacer Design
BACKGROUND: The study objective of this pilot study was to determine the lung delivery of HFA-134a-beclomethasone dipropionate (HFA-BDP; QVAR™) and CFC-beclomethasone dipropionate (CFC-BDP; Becloforte™) with and without the add-on spacers, Aerochamber™, and Volumatic™. The smaller particles of HFA-BDP were presumed to produce greater lung deposition using spacers, with and without a delay [i.e., metered dose inhaler (MDI) actuation into the spacer and subsequent inhalation 0 and 2 sec later], compared with the larger particles of CFC-BDP. The study included a comparison of breathhold effects (i.e., 1 and 10-sec breatholds) on lung deposition. METHODS: The study was an open-label design and utilized healthy subjects (n = 12 males). Each arm of the study contained three subjects; thus, outcomes were not powered to assess statistical significance. HFA-BDP and CFC-BDP were radiolabeled with technetium-99m and delivered to subjects. RESULTS: Results showed that the small particle HFA-BDP lung deposition averaged 52% and was not affected by the use of Aerochamber with or without a spacer delay. The oropharyngeal deposition of HFA-BDP was reduced from approximately 28% to 4% with the Aerochamber. Lung deposition with the large particle CFC-BDP was 3-7% and generally decreased with Aerochamber or Volumatic. A 2-sec time delay between actuation and breath plus the spacer reduced lung deposition slightly but reduced oropharygeal deposition substantially (84% down to 3-20%) using the Aerochamber or Volumatic with and without a spacer delay. HFA-BDP lung deposition was dependent on the breathhold. Lung deposition with HFA-BDP was reduced by 16% with a 1-sec versus 10-sec breathhold. The difference was measured in the increased exhaled fraction, confirming that smaller particles need time to deposit and are exhaled if there is a reduced breathhold. The large particle CFC-BDP lung deposition was not affected by breathhold. CONCLUSIONS: The use of Aerochamber or Volumatic spacers with HFA-BDP did not alter lung deposition but it did reduce oropharyngeal deposition. However, HFA-BDP displayed reduced oropharyngeal deposition without a spacer.
15
Deposition of pressurised aerosols in the human respiratory tract.
Stephen P. Newman, D Pavia, Folke Morén et al. · Thorax · 1981 · 378 citations · Full text
William W. Busse, Shari A. Brazinsky, Kraig W. Jacobson et al. · Journal of Allergy and Clinical Immunology · 1999 · 261 citations · Full text