Clinical Cardiology · 2001 · 24 citations · 11 references
MedicineCardiologyPharmacologyCardiovascular PharmacotherapyClinical PharmacologyInterventional CardiologyCardiac Risk AssessmentCardiovascular Drug SafetyCardiovascular MonitoringCoronary Artery DiseaseIschemic Heart DiseaseStress TestingCardiac Stress TestingContinuous Infusion PharmacologyCoronary Physiologic AssessmentDobutamine Stress ImagingPretest Risk EstimationSystolic Blood Pressure
BACKGROUND: Dobutamine pharmodynamics require approximately 10 min to reach steady state. Despite this, standard dobutamine stress echo typically uses 3-min stages of advancing dobutamine doses because of safety concerns. HYPOTHESIS: In patients with a high pretest probability of coronary artery disease (CAD), a continuous infusion of high-dose dobutamine is a feasible and safe method for performing a dobutamine stress test. METHODS: Forty-seven consecutive patients (mean age 64 +/- 11 years) with 3.0 +/- 1.4 cardiac risk factors underwent dobutamine stress testing utilizing a single, high-dose (40 mcg/kg/min), continuous dobutamine infusion. The 40 mcg/kg/min infusion was continued for up to 10 min or until a test endpoint had been reached. If a test endpoint was not achieved, atropine (up to 1.0 mg) was added. RESULTS: Heart rate rose from 71 +/- 12 to 137 +/- 18 beats/min at peak (p<0.0001) with a concomitant change in systolic blood pressure (143 +/- 35 vs. 167 +/- 38 mmHg; p = 0.001) but no change in diastolic blood pressure (74 +/- 19 vs. 75 +/- 18 mmHg; p = NS). Target heart rate was achieved in 20 of 47 (43%) patients with accelerated dobutamine alone and in 34 of 47 (72%) with the addition of atropine. An average of 11.6 +/- 3.7 min was required to obtain target heart rate. Subjective sensations from the dobutamine occurred in 49% of patients (palpitations 21%, nausea 6%, chest pain 6%, headache 6%, dizziness 13%), mild arrhythmia in 48% of patients (ventricular premature beats 38%, supraventricular tachycardia 10%), and one patient had nonsustained ventricular tachycardia. CONCLUSION: A single, high-dose (40 mcg/kg/min) dobutamine-atropine protocol provides an efficient means of performing dobutamine stress echocardiography with a similar symptom profile as conventional dobutamine infusion protocols in patients with a high pretest probability of CAD. Randomized, controlled studies will be necessary to assess the sensitivity and specificity of this accelerated dobutamine echo protocol.
11
The Physicians' Desk Reference
Jay S. Cohen · Archives of Internal Medicine · 1996 · 433 citations
Pharmacy, Pharmaceutical Policy, Drug Approval Processes +12