Concepedia

Publication | Closed Access

Inflection-point method of interpreting emissive probe characteristics

280

Citations

22

References

1979

Year

Abstract

The use of emissive Langmuir probes in unmagnetized and weakly magnetized multidipole plasmas is investigated. It is shown that plasma potential, plasma electron temperature, and probe temperature can be determined from one probe characteristic curve. Data indicate that the inflection point of the current-voltage curve gives the plasma potential to an accuracy the order of the probe temperature Tw/e for weak probe emission. Effects of space-charge limiting and contamination of the probe are presented.

References

YearCitations