Field Advanced Water Control Techniques Using Gel Systems

Pascal Baylocq, Jean-Jacques Féry, Alan G. Grenon

Abu Dhabi International Petroleum Exhibition and Conference · 1998 · 12 citations · 4 references

Concepts

Abstract

Abstract In the past few years, gel treatments have been considered to have an interesting potential for water shut off applications and improvement of the near wellbore injection profiles. This paper describes different applications using several types of gels, and details the lab and field procedures to ensure an efficient treatment. Polyacrylamide crosslinked gels have been successfully used to seal a water zone in a sandstone allowing the production of a bottom gas layer or to improve the conformance of the near wellbore injection profile in naturally fractured carbonates. Silicate gels were also used in the Middle East to shut off, during the drilling phase, several high pressure water flooded layers in order to avoid any crossflow between layers during the cement setting and the production phase. This paper describes some of the gel evaluation laboratory tests and different field applications. Procedures and recommendations for a proper formulation selection and an efficient gel placement are also presented.

References

4