American Industrial Hygiene Association Journal · 1980 · 18 citations · 0 references
Health ProfessionsRespiratory TherapyAir ConditioningPulmonary Function TestingVentilationAirway ProtectionLung-protective VentilationMechanical VentilationRespiratory ProtectionAerosol ProtectionContinuous FlowFace Seal LeakageLung ProtectionRespirator Performance EvaluationSubjectsSupplied-air Respirators
Protection Factors provided by 25 NIOSH approved supplied-air respirators were determined while the devices were worn by a panel of test subjects anthropometrically selected to represent adult facial sizes. Polydispersed DOP aerosol was used for respirator fit tests on continuous flow, demand, and pressure-demand respirators. Based on facepiece leakage measurements it appears that demand-type respirators should neither be used nor approved. The highest level of protection was provided by pressure-demand devices.