Circulation Arrhythmia and Electrophysiology · 2015 · 178 citations · 19 references
MedicineCardiologyBiomedical ImagingElectrophysiologyInterventional CardiologyAblation TherapyAtrial ElectrophysiologyAtrial FibrillationCatheter AblationElectrophysiological MappingIntracardiac ElectrophysiologyAblation Site LocalizationAtrial Activation MappingAtrial Electrogram AnalysisAtrial Fibrillation MappingAtrial MappingCatheter Ablation MappingIntracardiac ElectrogramsPulmonary Vein Isolation
BACKGROUND: New approaches to ablation of atrial fibrillation (AF) include focal impulse and rotor modulation (FIRM) mapping, and initial results reported with this technique have been favorable. We sought to independently evaluate the approach by analyzing quantitative characteristics of atrial electrograms used to identify rotors and describe acute procedural outcomes of FIRM-guided ablation. METHODS AND RESULTS: All FIRM-guided ablation procedures (n=24; 50% paroxysmal) at University of California, Los Angeles Medical Center were included for analysis. During AF, unipolar atrial electrograms collected from a 64-pole basket catheter were used to construct phase maps and identify putative AF sources. These sites were targeted for ablation, in conjunction with pulmonary vein isolation in most patients (n=19; 79%). All patients had rotors identified (mean, 2.3±0.9 per patient; 72% in left atrium). Prespecified acute procedural end point was achieved in 12 of 24 (50%) patients: AF termination (n=1), organization (n=3), or >10% slowing of AF cycle length (n=8). Basket electrodes were within 1 cm of 54% of left atrial surface area, and a mean of 31 electrodes per patient showed interpretable atrial electrograms. Offline analysis revealed no differences between rotor and distant sites in dominant frequency or Shannon entropy. Electroanatomic mapping showed no rotational activation at FIRM-identified rotor sites in 23 of 24 patients (96%). CONCLUSIONS: FIRM-identified rotor sites did not exhibit quantitative atrial electrogram characteristics expected from rotors and did not differ quantitatively from surrounding tissue. Catheter ablation at these sites, in conjunction with pulmonary vein isolation, resulted in AF termination or organization in a minority of patients (4/24; 17%). Further validation of this approach is necessary.
19
Spatial and temporal organization during cardiac fibrillation
Richard A. Gray, Arkady M. Pertsov, José Jalife · Nature · 1998 · 967 citations
Medicine, Cardiology, Neuroscience +14
Stable Microreentrant Sources as a Mechanism of Atrial Fibrillation in the Isolated Sheep Heart
Ravi Mandapati, Allan C. Skanes, Jay Chen et al. · Circulation · 2000 · 728 citations
Medicine, Cardiology, Physiology +17
Driver Domains in Persistent Atrial Fibrillation
Michel Haïssaguerre, Mélèze Hocini, Arnaud Denis et al. · Circulation · 2014 · 723 citations
Medicine, Bioengineering, Cardiology +17