Journal of Hand Surgery (European Volume) · 1998 · 75 citations · 4 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryJoint Replacement SurgeryOrthopedicsRheumatologyJoint DiseaseJoint DisordersJoint PathologyJoint Replacement MaterialsJoint SurgeryOsteoarthritisHand Joint ArthroplastyInterposition ArthroplastyInterpositional ArthroplastyOsteoarthritis Of The HandRetrospective Case StudyThumb Carpometacarpal OsteoarthritisTotal Joint ArthroplastyWrist Arthroplasty
In this retrospective study of 26 patients with arthritis of the thumb carpometacarpal joint, we report the use of expanded polytetrafluoroethylene (ePTFE) (Gore-Tex) and polypropylene (Marlex) as interpositional materials for resection arthroplasty of the trapeziometacarpal joint. We have compared the results with those of "conventional" tendon interposition and those in the literature. In three patients the use of ePTFE (Gore-Tex) was complicated by marked clinical synovitis, resembling findings in silicone synovitis. Therefore, the use of ePTFE has been discontinued. Polypropylene seems to be a valuable alternative to tendon interposition arthroplasty.
4
Basal Joint Arthrosis of the Thumb
Richard I. Burton · Orthopedic Clinics of North America · 1973 · 93 citations