Journal of Heat Transfer · 2005 · 82 citations · 12 references
EngineeringMechanical EngineeringHeat TransferThermal AnalysisThermodynamicsHeat ExchangersHeat FlowHeat Transfer AnalysisHeat Transfer FundamentalsHeat Transfer ModelingThermal DesignFlow Rate DependenceFlow Through Heat ExchangersHeat Exchanger DesignHeat Exchanger PerformanceHeat Exchanger Performance AnalysisPlate Heat ExchangersPressure DropPressure-drop Modeling
An experimental and theoretical study of the effect of flow maldistribution from port to channel on the thermal performance of single and multipass plate heat exchangers is presented. In general, flow maldistribution brings about an increase in pressure drop and decrease of the thermal performance in heat exchangers. This deterioration is found to depend on flow rate, number of channels, and port size. Experiments show that analytical predictions of pressure drop and thermal performance in presence of flow maldistribution are quite accurate for practical purposes. The results indicate that under identical conditions, maldistribution is more severe in Z-type plate heat exchanger compared to U type. Multipassing is found to reduce the maldistribution effect significantly. An insight to the physical aspects of maldistribution and its possible reduction through proper design strategy are also presented.
12