Journal of Hydraulic Engineering · 2006 · 33 citations · 5 references
EngineeringCivil EngineeringFlow AssuranceHydraulic EngineeringHydraulicsChannel DesignFlow MeasurementOpen-channel FlowRiver HydraulicsWeir HydraulicsDischarge CoefficientFlow Measurement Using WeirsReynolds NumberWeir Discharge CoefficientWeir Flow CharacteristicsWeir FlowsWeir Head-discharge RelationshipsWeirs
Slit weirs designed to measure small discharges in open channel flows are investigated. Experimental data available in the literature are added to study the effect of the slit width. An explicit relation for the discharge coefficient is obtained by a conventional Reynolds number definition. The discharge coefficient is modified to increase the working range of slit weirs for small values of head to slit-width ratios.
5