Comparison of Cerebral Blood Flow Measured by Laser- Doppler Flowmetry and Hydrogen Clearance in Cats after Cerebral Insult and Hypervolemic Hemodilution

Michael S. Kramer, P. Vinall, Leonid I. Katolik, Frederick A. Simeone

Neurosurgery · 1996 · 33 citations · 38 references

Concepts

Abstract

Laser-Doppler flowmetry provides a continuous measurement of blood flow without violating the natural state of circulation. The linearity of the laser-Doppler and hydrogen clearance methods of blood flow measurement were compared using a protocol that produced changes in cerebral blood flow that might be experienced in a neurosurgical setting. Cerebral blood flow was measured in both hemispheres of 12 adult cats during the snaring of one common carotid artery, the intracisternal injection of 5 mg of 5-hydroxytryptamine creatinine sulfate, and hypervolemic hemodilution, which produced a 25% reduction in blood hematocrit. The percentage of baseline laser-Doppler flowmetry and hydrogen clearance flows showed an acceptable degree of correlation (R2 = 0.762) over the range of cerebral blood flows measured. More rigorous analysis using Bland and Altman's difference against mean test showed that 10 minutes after hemodilution, the two methods displayed a level of variation outside the limits of agreement (-21.85 to 22.03%). Laser-Doppler flowmetry provided a noninvasive and continuous measure of blood flow, increasing the ability to observe instantaneous changes in cerebral microcirculation. However, laser-Doppler flowmetry did not record absolute blood flow, was affected by cerebral tissue shrinkage, and did not accurately measure flow under conditions of changed blood hematocrit.

References

38