Pharmaceutical ScienceBioorganic ChemistryCommon Degradation ProductsPharmaceutical ChemistryChemical DerivativeDrug ResistanceMedicinal ChemistryBioanalysisAnalytical ChemistrySensitive Spectrophotometric MethodsChromatographySpectrophotometric DeterminationBiochemistryAntibacterial AgentChromatographic AnalysisPharmacologyNatural SciencesPenicillin DerivativesMedicineCertain π-AcceptorsDerivative (Chemistry)Drug DiscoveryDrug Analysis
Two simple and sensitive spectrophotometric methods are described for the determination of six penicillin derivatives. The methods are based on the reaction of these drugs as n-electron donors with either 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) or 7,7,8,8-tetracyanoquinodimethane (TCNQ) as pi-acceptors, to give a highly coloured radical anion. The coloured products are quantified spectrophotometrically at 460 and 842 nm for DDQ and TCNQ, respectively. The optimization of the different experimental conditions is described. The interference from streptomycin sulphate and common degradation products was also studied. The proposed methods were applied successfully to the determination of the different penicillins investigated, either in pure or dosage forms, with good accuracy and precision. The results were compared with those given by the official United States Pharmacopeial XXI method.