EP Europace · 2011 · 180 citations · 22 references
MedicineCardiologyClinical CardiologyElectrophysiologyAtrial ElectrophysiologyAtrial FibrillationCardiac ArrhythmiasCardiovascular MonitoringElectrocardiographyHeart FailureAtrial Fibrillation AssessmentAtrial Fibrillation DetectionAtrial Fibrillation MonitoringCardiac Monitoring SystemsContinuous MonitoringDevice-detected Atrial FibrillationDevice-related ArrhythmiasHome Monitoring Systems
AIMS: Uncertainty exists over the importance of device-detected short-duration atrial arrhythmias. Continuous atrial diagnostics, through home monitoring (HM) technology (BIOTRONIK, Berlin, Germany), provides a unique opportunity to assess frequency and quantity of atrial fibrillation (AF) episodes defined as atrial high-rate events (AHRE). METHODS AND RESULTS: Prospective data from 560 heart failure (HF) patients (age 67 ± 10 years, median ejection fraction 27%) patients with a cardiac resynchronization therapy (CRT) device capable of HM from two multi-centre studies were analysed. Atrial high-rate events burden was defined as the duration of mode switch in a 24-h period with atrial rates of >180 beats for at least 1% or total of 14 min per day. The primary endpoint was incidence of a thromboembolic (TE) event. Secondary endpoints were cardiovascular death, hospitalization because of AF, or worsening HF. Over a median 370-day follow-up AHRE occurred in 40% of patients with 11 (2%) patients developing TE complications and mortality rate of 4.3% (24 deaths, 16 with cardiovascular aetiology). Compared with patients without detected AHRE, patients with detected AHRE>3.8 h over a day were nine times more likely to develop TE complications (P= 0.006). The majority of patients (73%) did not show a temporal association with the detected atrial episode and their adverse event, with a mean interval of 46.7 ± 71.9 days (range 0-194) before the TE complication. CONCLUSION: In a high-risk cohort of HF patients, device-detected atrial arrhythmias are associated with an increased incidence of TE events. A cut-off point of 3.8 h over 24 h was associated with significant increase in the event rate. Routine assessment of AHRE should be considered with other data when assessing stroke risk and considering anti-coagulation initiation and should also prompt the optimization of cardioprotective HF therapy in CRT patients.
22
A. John Camm, Paulus Kirchhof, Gregory Y.H. Lip et al. · European Heart Journal · 2010 · 5.9K citations · Full text
Validation of Clinical Classification Schemes for Predicting Stroke
Brian F. Gage, Amy D. Waterman, William D. Shannon et al. · JAMA · 2001 · 4.8K citations
Impact of Atrial Fibrillation on the Risk of Death
Emelia J. Benjamin, Philip A. Wolf, Ralph B. D’Agostino et al. · Circulation · 1998 · 4.6K citations
Medicine, Cardiology, Aging +16
A Comparison of Rate Control and Rhythm Control in Patients with Atrial Fibrillation
D G Wyse, A.L. Waldo, John Dimarco et al. · New England Journal of Medicine · 2002 · 4.4K citations · Full text