MedicineOncologyRadiation OncologyClinical Radiation OncologyThoracic Radiation OncologyTreatment PlanningExternal Beam RadiotherapyIntensity-modulated RadiotherapyRadiation TherapyRadiation Treatment PlanningStereotactic RadiotherapyTreatment Planning PhysicsFlattening Filter-free BeamsPlan Quality AssessmentPlan Quality MetricsStandard Of PracticeStereotactic Treatment PlanningTreatment Delivery MetricsTreatment Plan EvaluationVolumetric Modulated Arc Therapy Planning
BACKGROUND: Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time compared to flattening filter beams (i.e. standard, STD) for several patient groups. We hypothesize that the treatment plan quality is comparable while the treatment delivery time of volumetric modulated arc therapy (VMAT) is considerably shorter using FFF beams, especially for stereotactic treatments. METHODS: A total of 120 patients treated for head and neck (H&N) tumors, high-grade glioma, prostate cancer, early stage lung cancer and intra-cranial metastatic disease (both single and multiple metastases) were included in the study. For each cohort, 20 consecutive patients were selected. The plans were generated using STD- and FFF-VMAT for both 6 MV and 10 MV, and were compared with respect to plan quality, monitor units and delivery time using Wilcoxon signed rank tests. RESULTS: For H&N and high-grade gliomas, there was a significant difference in homogeneity index in favor for STD-VMAT (p < 0.001). For the stereotactic sites there were no differences in plan conformity. Stereotactic FFF-VMAT plans required significantly shorter delivery time compared to STD-VMAT plans (p < 0.001) for higher dose per fraction, on average 54.5% for 6 MV and 71.4% for 10 MV. FFF-VMAT generally required a higher number of MU/Gy (p < 0.001), on average 7.0% for 6 MV and 8.4% for 10 MV. CONCLUSION: It was generally possible to produce FFF-VMAT plans with the same target dose coverage and doses to organs at risk as STD-VMAT plans. Target dose homogeneity tended to be somewhat inferior for FFF-VMAT for the larger targets investigated. For stereotactic radiotherapy, FFF-VMAT resulted in a considerable time gain while maintaining similar plan quality compared to STD beams.
22
Volumetric modulated arc therapy: IMRT in a single gantry arc
Karl F. Otto · Medical Physics · 2007 · 1.9K citations · Full text
Medicine, Radiation Oncology, Clinical Radiation Oncology +16
Wilko F.A.R. Verbakel, J.P. Cuijpers, D. Hoffmans et al. · International Journal of Radiation Oncology*Biology*Physics · 2009 · 447 citations
Eugenio Vanetti, Alessandro Clivio, Giorgia Nicolini et al. · Radiotherapy and Oncology · 2009 · 323 citations