Journal of Medical Engineering & Technology · 1979 · 30 citations · 3 references
MedicinePhysical MedicineRehabilitation MedicineBiomechanicsOrthotic TherapyOrthoticsGait AnalysisGait Analysis In OrthoticsGait AssessmentGait BiomechanicsOrthotic BiomechanicsOrthotic DevicesForce PlatformsGaitGait Cycle AnalysisGait KinematicsGround Reaction Force AnalysisGround Reaction ForcesLocomotor Function AssessmentOrthotic Effects On Gait
Introduction The Orthotic Research and Locomotor Assessment Unit (ORLAU) is engaged in research into particular ambulation problems and in the clinical evaluation of individual patient gait disorders. One of the most important areas of the work undertaken is the evaluation of forces generated during walking. Perhaps the simplest way of deriving this data is to monitor the ground reaction forces during the stance phase of the cycle. The study of ground reaction forces during ambulation has been undertaken over a considerable period, and Elftman [3] reported the now classic pattern of forces during stance phase. Post war research exemplified by Bresler and Frankel [1] and Murray et al [5] led to more sophisticated designs of force platform and such devices are now available from at least one instrument manufacturer (Kistler), this being the type installed at ORLAU. The vast majority of work carried out on force platforms is of a research nature, and although these devices have led to a much better understanding of the gait cycle, they have made little impact on clinical evaluation of individual patient problems. This is in no small part due to the manner in which results are presented in single component form for the three directions of interest, that is in vertical, horizontal, fore-aft and horizontal lateral directions. These force components can be used to derive joint forces and moments acting at the ankle, knee and hip as demonstrated by Bresler and Frankel [ 1 ] and Hughes [4], but the laborious nature of that process is intimidating to most clinicians. What is required is an immediate visual presentation of the forces acting in a particular plane combined with a visual image of the patient's ambulation. Thus a vector of the forces acting in any visual plane, deriving from centre of force would enable a clinician to see immediately the implication of those forces to the joints in question. A system in which the outputs from a force plate are used to produce a force vector has been developed at Moss Rehabilitation hospital by Cook et al [2]. It is also known that the Valley Instrument Company* is preparing a prototype of a production model that is believed will be suitable and feasible for both research and clinical use. In this system, the force plate outputs are used, in conjunction with analogue circuits, to produce Lissajous figures by deflecting a laser beam with galvanometer mirrors. The resulting 'line' is optically combined with a view of the patient and recorded on film, thus superimposing a force vector on the limb to be studied. This system has a clear potential for use as a clinical tool, however an increasing amount of video recording as opposed to cine film is being used in the analysis of gait. The main disadvantage of film as a recording medium is the inherent delay involved in processing the film, preventing an 'on the spot' analysis of a patient disorder. Furthermore, it often happens that on the eventual return of a film from processing, insufficient data has been collected, the patient has stepped incorrectly on the plate, or some error has been made. Figure 1. Example of video displayed vector.
3
The forces and moments in the leg during level walking
Eshel Bresler · Medical Entomology and Zoology · 1950 · 368 citations
Education, Kinesiology, Physiology +12