Review of Scientific Instruments · 1984 · 18 citations · 11 references
Natural SciencesRadiologyBiomedical ImagingDiagnostic ImagingPlasma PhysicsComputed TomographyComputed Tomography PhysicsPlasma DiagnosticsBeam Power DensityMaximum Entropy EstimationTime Resolution
This paper describes a new diagnostic technique to decode information contained in the spectral and spatial distribution of photons emitted by fast neutral beam particles and provide an estimate of the 2-D beam density distribution function in a cross-sectional slice. By scanning Doppler-shifted Hα radiation from the fast beam particles at a number of peripheral locations around the beam axis, tomographic reconstructions of the beam distribution with spatial resolution Δx≂2 cm and time resolution Δt≂10 ms can be made. Using a maximum entropy reconstruction algorithm (making no symmetry assumptions), experimental reconstructions are presented of the 2-D profile of the beam generated by the prototype JET source for each of the Doppler-shifted line radiation components. Applications of this image processing technique in other areas of high-temperature plasma diagnostic development are discussed briefly.
11
Reconstruction of Three Dimensional Structures from Electron Micrographs
David J. De Rosier, A. Klug · Nature · 1968 · 1.3K citations
Medicine, Biophysics, Cell Biology +12
Image reconstruction from incomplete and noisy data
S. F. Gull, G.J. Daniell · Nature · 1978 · 965 citations
Doppler shift spectroscopy of powerful neutral beams
C. F. Burrell, William S. Cooper, R. R. Smith et al. · Review of Scientific Instruments · 1980 · 71 citations · Full text