Concepedia

Publication | Closed Access

Peroneal nerve repetitive nerve stimulation test: Its value in diagnosis of myasthenia gravis and Lambert–Eaton myasthenic syndrome

22

Citations

14

References

1995

Year

Abstract

We have developed a repetitive nerve stimulation (RNS) technique for the peroneal nerve. Normal limits for the decremental responses for the anterior tibialis and extensor digitorum brevis muscles are 6-21% at the low rate of stimulation and 44-70% at the high rate of stimulation. These values exceed the normal limits for other commonly tested muscles. This may be due to the lower safety factor for neuromuscular transmission for the anterior tibialis and extensor digitorum brevis muscles. We present 4 cases in which the peroneal nerve RNS test was crucial for the diagnosis of the limb-girdle form of MG or LEMS. Thus, we conclude that, in a small number of patients with neuromuscular transmission disorders, the peroneal nerve RNS test is needed for confirmation of disease.

References

YearCitations