The Initial Response to Inhaled Nitric Oxide Treatment for Intensive Care Unit Patients with Acute Respiratory Distress Syndrome

Chien‐Wei Hsu, David Lin Lee, Shoa-Lin Lin, Shu‐Fen Sun, Hsueh‐Wen Chang

Respiration · 2007 · 32 citations · 37 references

Concepts

Abstract

BACKGROUND: Inhaled nitric oxide (INO) can improve hypoxemia and reduce pulmonary hypertension, but there is a wide range of response to INO. OBJECTIVES: The aim of this study was to evaluate the effect of different INO concentrations in acute respiratory distress syndrome (ARDS) patients. METHODS: Thirty-two adult ARDS patients who were supported by mechanical ventilator were included. INO was given at a concentration of 1, 5, 10, 20 and 40 ppm, sequentially. Arterial blood gas and mean pulmonary artery pressure (MPAP) were measured 30 min after INO concentrations changed. RESULTS: There was a significant increase in PaO(2)/FiO(2) (p < 0.0001) and a decrease in pulmonary vascular resistance index and MPAP (p < 0.0001) after INO use. INO concentrations required for improving oxygenation were in the range of 1-20 ppm, whereas concentrations required for decreasing MPAP were in the range of 1-40 ppm. PaO(2)/FiO(2) worsened when the INO dose was adjusted above 20 ppm. Sixty-nine percent of ARDS patients were responders; 31% of them were nonresponders. Among responders, 64% of patients responded at 1 ppm, 36% at 5 ppm. CONCLUSIONS: The optimal doses for improving oxygenation and reducing PAP differ. The maximum PaO(2)/FiO(2) was observed at a lower INO concentration than that required for the minimal MPAP. There was no further improvement in PaO(2)/FiO(2) when the INO dose was adjusted above 20 ppm. Higher doses of INO treatment worsened oxygenation.

References

37