IEEE Transactions on Energy Conversion · 2004 · 138 citations · 22 references
Electrical EngineeringEnergy Efficient DriveEngineeringElectric MachineEnergy EfficiencyEnergy ManagementMotor DriveLoss Model ControllerMechatronicsEfficiency OptimizationElectrical DriveSystems EngineeringInterior Pm Motor
In this paper, the problem of efficiency optimization in vector-controlled interior permanent-magnet (PM) synchronous motor drives is investigated. A loss model controller is introduced that determines the optimal d-axis component of the stator current that minimizes power losses. For the implementation of the suggested controller, the knowledge of the loss model is not required since an experimental procedure is followed to determine its parameters. Furthermore, it is shown that the loss model of the interior PM motor can be used as a basis for deriving loss minimization conditions for surface PM synchronous motors and synchronous reluctance motors as well. Experimental results of an interior PM motor are presented to validate the effectiveness of the proposed method and demonstrate the operational improvements.
22
Power Electronics and AC Drives
B.L. Jones · Electronics and Power · 1987 · 522 citations
High-power Electronics, Electrical Engineering, Engineering +4
Reluctance synchronous machines and drives
Choice Reviews Online · 1997 · 186 citations