Roentgen Measurement of Visual Acuity in Cataractous Eyes

R. R. Newell, W.E. Borley

Radiology · 1941 · 14 citations · 0 references

Concepts

Abstract

The Nature of Vision by Roentgen Ray Roentgen (1) in 1896 believed x-rays invisible, but in 1897 (2) reported that they could be seen by the unaided eye. Desjardins (3) as late as 1931 wrote that they are invisible. Taft (4) expressed astonishment that so easy a demonstration had been missed by almost all radiologists, and gave references to early workers whose writings in this respect had been ignored, among others Edison. Since the appearance of Pirie's paper in 1934 (5, 6) we have used “Pirie's test” in cases of ocular foreign body, seeking to distinguish the single retinal shadow of an intraocular foreign body from the double shadow of an extraocular one, seldom with success. Being curious about the unsettled question as to whether x-rays stimulate the retina directly or by production of fluorescence in some part of the eye, we irradiated in the dark the opened eyeball just removed from a rabbit after two hours' dark adaptation. The irradiation was about 200,000 times the threshold for x-ray vision, i.e., at 100,000 r per minute (for one second). The lens fluoresced but the retina did not. Of course the brightness of the retinal image even with observers' pupils well dilated is only about 0.03 the brightness of the object viewed. That is to say, a fluorescent sheet would have to be 30 times as bright to see by looking at it, as it would need be if put in contact with the retina. There might, to be sure, be some fluorescent substance in the human retina that is lacking in the rabbit's retina. Indeed, we do not know whether a rabbit can see x-rays at all. We thought it safe to irradiate a human eye at 1,000 r per min. (for 1 second three times). We chose a patient who had had the lens extracted together with its capsule. On observing her eye during irradiation at 1,000 r per min., from the side, no glow could be seen in the pupil. The lens of a normal eye fluoresced visibly when so irradiated, as did the skin, also. Patient and observers were, of course, completely dark-adapted. We have calculated the amount of energy needed for vision by x-ray. The threshold value of 1/2 r per minute to a spot measuring 1 sq. mm. on the retina amounts to an absorption of 2 X 10-5 ergs per second in the 50 μ thickness of the rod layer. The threshold for light (7) is about 4 X 10-9 ergs per second. On an energy basis, therefore, light is 5,000 times as efficient as x-rays for retinal stimulation. The best evidence that x-ray vision and ordinary vision are similarly dependent on visual purple is the similar course of dark-adaptation in both. Figure 1-B is a rough curve of dark-adaptation for one of us (R. R. N.). X-ray and light both show a relative central scotoma for low intensities. We attribute this to the greater sensitivity of the rods compared to the cones, for the fovea contains only cones.