Reports of Practical Oncology & Radiotherapy · 2015 · 12 citations · 12 references
MedicineRadiation OncologyRadiologyRadiation DosimetryRadiation TransportTreatment PlanningAbsorbed DoseBrachytherapy DosimetryExternal Beam DosimetryMonte Carlo DosimetryRadiation TherapyTreatment Planning Dose CalculationBrachytherapy Dose CalculationBrachytherapy Dose DistributionBrachytherapy Phantom DosimetryBrachytherapy Photon DosimetryDepth Dose DistributionDose Distribution CalculationsRadial Dose DistributionSource Dosimetry
AIM: The aim of this study is to evaluate the dose distribution of the Flexisource (192)Ir source. BACKGROUND: Dosimetric evaluation of brachytherapy sources is recommended by task group number 43 (TG. 43) of American Association of Physicists in Medicine (AAPM). MATERIALS AND METHODS: MCNPX code was used to simulate Flexisource (192)Ir source. Dose rate constant and radial dose function were obtained for water and soft tissue phantoms and compared with previous data on this source. Furthermore, dose rate along the transverse axis was obtained by simulation of the Flexisource and a point source and the obtained data were compared with those from Flexiplan treatment planning system (TPS). RESULTS: The values of dose rate constant obtained for water and soft tissue phantoms were equal to 1.108 and 1.106, respectively. The values of the radial dose function are listed in the form of tabulated data. The values of dose rate (cGy/s) obtained are shown in the form of tabulated data and figures. The maximum difference between TPS and Monte Carlo (MC) dose rate values was 11% in a water phantom at 6.0 cm from the source. CONCLUSION: Based on dosimetric parameter comparisons with values previously published, the accuracy of our simulation of Flexisource (192)Ir was verified. The results of dose rate constant and radial dose function in water and soft tissue phantoms were the same for Flexisource and point sources. For Flexisource (192)Ir source, the results of TPS calculations in a water phantom were in agreement with the simulations within the calculation uncertainties. Furthermore, the results from the TPS calculation for Flexisource and MC calculation for a point source were practically equal within the calculation uncertainties.
12
The Physics of Radiation Therapy
James B. Smathers · Journal of Applied Clinical Medical Physics · 2003 · 754 citations · Full text
The Paris System in Interstitial Radiation Therapy
B Pierquin, A. Dutreix, C.H. Paine et al. · Acta Radiologica Oncology Radiation Physics Biology · 1978 · 191 citations · Full text
Spectra and air-kerma strength for encapsulated 192Ir sources
Jette Borg, D. W. O. Rogers · Medical Physics · 1999 · 77 citations · Full text
A dosimetric study on the high dose rate Flexisource
Domingo Granero, José Pérez‐Calatayud, E. Casal et al. · Medical Physics · 2006 · 75 citations