Critical Care Medicine · 1978 · 79 citations · 0 references
MedicineSurgeryHemodynamic ManagementUltrasonographyVascular SurgeryDoppler UltrasoundHemodynamicsThrombosisVascular UltrasonographyVascular UltrasoundArterial Doppler EvaluationArterial Occlusion ManagementCannulation Success RatesFlow State DetectionRadial Artery CannulationRadial Artery Occlusion
Radial artery function was studied in 114 consecutive patients by arteriography, Doppler ultrasound flow detection, and physical examination following prolonged (1-10 days) percutaneous cannulation with a single type of 20-gauge catheter. Cannulations lasting 1-3 days produced 11% arterial occlusion, whereas those lasting 4-10 days induced 29% incidence of occlusion (p less than 0.05). In addition, a significantly higher incidence of cannula dysfunction (38% versus 18%, p less than 0.05) and thrombus formation (0-3+ scale) was also observed in the group cannulated 4-10 days as compared with the group of shorter duration. The risk of vascular complications arising from percutaneous radial artery cannulation with 20-gauge catheters increases markedly after 3 days.