Biomedical Optics Express · 2011 · 89 citations · 12 references
EngineeringBiomedical EngineeringBiomedical ImagingBiomedical OpticsDiagnostic ImagingOptical FlowOptical Transfer FunctionContrast AnalysisExperimental Results InterpretationPixel Size EffectsSpeckle Contrast
Practical laser speckle contrast analysis systems face a problem of spatial averaging of speckles, due to the pixel size in the cameras used. Existing practice is to use a system factor in speckle contrast analysis to account for spatial averaging. The linearity of the system factor correction has not previously been confirmed. The problem of spatial averaging is illustrated using computer simulation of time-integrated dynamic speckle, and the linearity of the correction confirmed using both computer simulation and experimental results. The valid linear correction allows various useful compromises in the system design.
12
Robust flow measurement with multi-exposure speckle imaging
Ashwin B. Parthasarathy, W. James Tom, Ashwini Gopal et al. · Optics Express · 2008 · 365 citations · Full text