IEEE Sensors Journal · 2015 · 10 citations · 34 references
Natural SciencesChemistryMaterials ScienceAnalytical ChemistryBiosensorsNanomaterialsChemical SensorsElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsElectrode MaterialsNanosensorsAmperometric BiosensorsAmperometric SensingAmperometric SensorsColloidal NanoparticlesGlassy Carbon ElectrodesHydrogen Peroxide BiosensorsNanomaterial-modified ElectrodesNanoparticles
Three novel nonenzymatic sensors based on the modification of a glassy carbon electrode with nanoparticles of Fe <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> , Cu <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , or Ni <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> Prussian blue (PB) derivatives are proposed herein. The Fe <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> -, Cu <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> -, and Ni <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> -modified PB nanoparticles were supported in an environmentally friendly chemical product known as melanin. The nanomaterials prepared were characterized by transmission electron microscopy images, electrochemical impedance spectroscopy, and cyclic voltammetry. The drop casting method was used to build the enzymeless sensors, which were able to catalyze the oxidation of hydrogen peroxide (H2O2) at +1.5 V. The calibration curves obtained by amperometry were linear in the range of 0.1-13 mmol L <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> . Several figures of merit were obtained in order to characterize the analytical electrochemical behavior of the as-prepared sensors. For instance, the detection limits achieved were 0.14, 0.32, and 0.57 μmol L <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> for the melanin-capped modified PB nanoparticle sensor containing, respectively, Fe <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> , Cu <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , and Ni <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> ions. These values are lower than the detection limits provided by other nonenzymatic sensors. The sensors were applied for the detection of H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> in tooth whitening gel. The results obtained were compared with those of the standard method.
34
Electrochemical Biosensors - Sensor Principles and Architectures
Dorothee Grieshaber, Robert MacKenzie, János Vörös et al. · Sensors · 2008 · 639 citations · Full text
Catechols as versatile platforms in polymer chemistry
Emilie Faure, Céline Falentin‐Daudre, Christine Jérôme et al. · Progress in Polymer Science · 2012 · 602 citations · Full text