American Journal of Neuroradiology · 2011 · 101 citations · 13 references
MedicineNeurologyRadiologyDiagnostic ImagingDiagnostic RadiologyNeuroradiologyBrain ImagingMagnetic Resonance ImagingMedical ImagingMetastatic Brain TumorsNeuro-oncologic ImagingNeuro-oncology Imaging3D Magnetic Resonance ImagingComparative Diagnostic PerformanceDiagnosis Of Brain MetastasesGradient Echo SequencesNeuroimaging Of Brain MetastasesT1-weighted ImagingThree-dimensional Imaging SequencesTurbo Spin Echo
BACKGROUND AND PURPOSE: MSDE preparation is a technique for black-blood imaging. Our purpose was to evaluate the usefulness of a 3D TSE sequence with MSDE preparation in detecting brain metastases by comparing it with conventional sequences. MATERIALS AND METHODS: Postcontrast images of 227 patients who were suspected of having brain metastasis were prospectively obtained by using 3 T1-weighted 3D sequences: a gradient-echo sequence (MPRAGE), TSE-noMSDE, and TSE-MSDE. The number of visualized blood vessels and the lesion-to-normal CNR were compared among the 3 sequences. An observer test involving 9 radiologists was performed, and their diagnostic performance by using TSE-MSDE, MPRAGE, and combined TSE-MSDE and MPRAGE was compared by means of an FOM as an index of diagnostic performance derived by the JAFROC analysis, sensitivity, FP/case, and reading time. RESULTS: TSE-MSDE resulted in significantly better vessel suppression than the other 2 methods. TSE with and without MSDE resulted in significantly higher CNRs than MPRAGE. In the observer test, significantly higher sensitivity and FOM as well as significantly shorter reading time were achieved by TSE-MSDE compared with MPRAGE, but FP/case was significantly higher with TSE-MSDE. Combined TSE-MSDE/MPRAGE resulted in significantly higher sensitivity and FOM and similar FP/case and reading time compared with MPRAGE alone. CONCLUSIONS: With blood vessel suppression and increased CNR, TSE-MSDE improves radiologists' performances in detecting brain metastases compared with MPRAGE, but it may increase FP results. Combined with MPRAGE, TSE-MSDE achieves high diagnostic performance while maintaining a low FP rate.
13
Douglas Kondziolka, Atul T. Patel, L. Dade Lunsford et al. · International Journal of Radiation Oncology*Biology*Physics · 1999 · 995 citations
Intracranial metastases from systemic cancer.
J. B. Posner, Norman L. Chernik · PubMed · 1978 · 622 citations
Medicine, Neurosurgery, Oncology +14
Jinnan Wang, Vasily L. Yarnykh, Thomas S. Hatsukami et al. · Magnetic Resonance in Medicine · 2007 · 220 citations · Full text
Veterinary Medicine, Bioengineering, Biomedical Engineering +17