Absolute measurements of water content using magnetic resonance imaging: Preliminary findings in an in vivo focal ischemic rat model

Weili Lin, Kilichan Gurleyik, Yushuang He, Richard P. Paczynski, William J. Powers, Chung Y. Hsu

Magnetic Resonance in Medicine · 2000 · 56 citations · 13 references

DOIFull text

Open access

Concepts

Abstract

Using a magnetic resonance (MR) imaging method, absolute measurements of in vivo brain water content were obtained in 15 male Long Evans rats that underwent a 90-min focal cerebral ischemia. A strong linear relationship (r = 0.80) with a slope of 1 was observed when correlating MR-measured water content to that obtained with the ex vivo wet/dry measurements. This effective spin-density-based method is the first-reported in vivo absolute quantification of brain tissue water content associated with a pathophysiological state and preliminary findings suggest that a noninvasive measurement of brain water content can be obtained with MRI.

References

13