Osteosynthesis of femoral neck fracture: The sliding-screw-plate with or without compression

Peter A. Frandsen, Poul Erik Andersen, Hardy Christoffersen, Per Thomsen

Acta Orthopaedica Scandinavica · 1984 · 37 citations · 16 references

DOIFull text

Open access

Concepts

Abstract

In a prospective study of 220 displaced femoral neck fractures treated with a sliding-screw-plate, the cases were allocated to osteosynthesis with or without compression. In surviving patients followed for at least 1 year, union occurred in 57/85 with compression and 58/71 without compression. At 2 years, necrosis was radiographically evident in 9/37 and 7/36 united fractures. Thus, compression cannot be recommended when displaced femoral neck fractures are treated with a sliding-screw-plate.

References

16