Water Resources Research · 1996 · 199 citations · 32 references
Natural SciencesEarth SciencesSoil SciencesEnvironmental ChemistryGeochemistrySoil ChemistryAir QualityAtmospheric GeochemistryGroundwater AgeGroundwater ContaminationAir Mass CompositionEnvironmental TracersGroundwater Age DatingGroundwater Age TracersGroundwater DatingGroundwater TableSoil Air CompositionYoung Water Fractions
CFCs are valuable tracers for dating young groundwater, but their use relies on knowing the initial concentration and assuming tracer stability. The study aims to test the chemical stability assumption of CFCs by examining degradation under anoxic conditions. Five field sites and two laboratory experiments measured CFC‑11 and CFC‑12 degradation rates ranging from 0.05 to 3×10⁵ pmol L⁻¹ yr⁻¹ under anoxic conditions. Site‑specific CFC excesses vary from 125 % in urban to 30 % in rural sites, and low‑pass filtering of soil‑air data enables reconstruction of local input anomalies, while degradation experiments reveal a constant 10‑fold lower reactivity of CFC‑12 compared to CFC‑11.
CFCs are useful tracers for age dating young water. Two critical assumptions are typically invoked: (1) the initial concentration needs to be known, and (2) the tracer must be stable. A series of 8000 CFC air data from four sites on the west European continent (from high‐alpine clean air down to urban sites) show site‐specific CFC excesses relative to the global background ranging from 125% at an urban site (Heidelberg) to only 30% at a rural site (Wachenheim). In both cases we find regular diurnal, weekly, and annual variations but also episodic variations due to changing air mass and sporadic local emission as well as a decrease of the CFC excess due to decreasing emissions in Europe. However, in soil air above the groundwater table the CFC excess variation is low‐pass filtered, allowing reconstruction of the site‐specific CFC input anomaly in relation to the global background. Thus local CFC soil air measurements can provide a valuable local correction factor for CFC dating and extend the applicability of CFC studies in specific environments. To investigate the chemical stability assumption, five field sites and two laboratory experiments show CFC 11 and CFC 12 degradation under anoxic conditions with degradation rates ranging from 0.05 up to 3×10 5 pmol L −1 yr −1 . However, the CFC 12/CFC 11 degradation ratio is found to be constant over six orders of magnitude, with CFC 12 always being less reactive by a factor of about 10.
32
C. J. Tranter · Journal of the Mechanics and Physics of Solids · 1959 · 18.5K citations
Floods, channel change, and the hyporheic zone
Steven M. Wondzell, Frederick J. Swanson · Water Resources Research · 1999 · 1.4K citations · Full text
T.H.E. Heaton, J. C. Vogel · Journal of Hydrology · 1981 · 503 citations
Eurybiades Busenberg, L. Niel Plummer · Water Resources Research · 1992 · 478 citations
Tritium/3He dating of shallow groundwater
Peter Schlösser, M. Stute, Helmut Dörr et al. · Earth and Planetary Science Letters · 1988 · 320 citations