Rapid Communications in Mass Spectrometry · 2004 · 42 citations · 23 references
Natural SciencesChemistryAnalytical ChemistryMass Spectrometric AnalysisOrganic ChemistryIonization TechniquesMass SpectrometryOzone ChemistryPhotoelectron SpectroscopyIonizationMechanismsOrganic Compound ReactionsOzoneSoft Ionization
Photoelectron resonance capture ionization (PERCI) is a soft and sensitive ionization method, based on the attachment of low-energy (<1 eV) photoelectrons to organic analyte molecules. PERCI has been developed in our laboratory for the real-time analysis of organic particles by mass spectrometry, and is employed here to monitor the heterogeneous reaction of ozone with oleic acid. Simplified identification of the reaction products is possible as a result of the soft nature of PERCI, giving predominantly the [M--H](-) ions. The major particle-phase products are identified as: 1-nonanal, nonanoic acid, 9-oxononanoic acid, and azelaic acid, consistent with proposed mechanisms. New insight into this well-studied heterogeneous reaction is gained as additional minor particle-phase products, consistent with the Criegee mechanism, are readily detected.
23
Smoking Rain Clouds over the Amazon
Meinrat O. Andreae, Daniel Rosenfeld, Paulo Artaxo et al. · Science · 2004 · 1.7K citations
Rudolf Criegee · Angewandte Chemie International Edition in English · 1975 · 1.4K citations