Publication | Closed Access
Contrast media as markers for glomerular filtration: A pharmacokinetic comparison of four agents
96
Citations
17
References
1988
Year
PharmacotherapyDrug FatePharmacokineticsRenal FunctionContrast MediaPharmacological StudyDrug PurityBioanalysisAnalytical ChemistryClinical ChemistryChronic Kidney DiseaseChromatographyPlasma ClearanceOphthalmologyContrast AgentPharmacologyEquilibrium DialysisUrologyPharmacokinetic ComparisonGlomerular FiltrationMedicineNephrologyAnesthesiologyDrug Analysis
In this study methods for the assay of the iodine-containing radiographic contrast agents metrizoate, amidotrizoate and iothalamate found in serum and urine have been developed. The method involved reverse-phase high-pressure liquid chromatography with spectrophotometric detection. This technique was used to compare the clearance of these agents, in a group of healthy female volunteers, after a single small-dose injection (5 ml, 2275-3235 mg). In the period 0-4 h after injection, serum elimination was approximated by a two-compartment model. However, a full description of drug fate in the body required at least three compartments. Plasma clearance was significantly different between agents with means of 191, 130, 144 and 121 ml/min for metrizoate, amidotrizoate, iothalamate and iohexol, respectively, whereas no difference was found between the renal/plasma clearance ratio. Protein binding measured with equilibrium dialysis did not suggest binding to serum proteins by any of these agents irrespective of concentration.
| Year | Citations | |
|---|---|---|
Page 1