A survey of the use of portable ultrasound for central vein cannulation on critical care units in the UK
22
Citations
11
References
2002
Year
Medical UltrasoundMinimally Invasive ProcedureThoracic UltrasoundInterventional RadiologySurgeryCritical Care UnitsPrimary CareCentral Vein CannulationVascular SurgeryUltrasound FacilitiesVenous DiseaseOutcomes ResearchUltrasoundCentral VeinPatient SafetyPortable UltrasoundVascular AccessMedicinePortable Ultrasound MachinesEmergency MedicineAnesthesiology
A questionnaire was sent to 288 critical care units in the UK to assess the use of portable ultrasound machines to assist central vein cannulation. There was a 58% response rate. Ultrasound guidance was used by 36 (21.6%) units for central vein cannulation. Of these, only four (11.1%) used it routinely and 25 (69.4%) used it when faced with a difficult vein cannulation. Half of the units with ultrasound facilities may be using it suboptimally. Of those units not using ultrasound for central vein cannulation, 70 (53%) said it was because of lack of equipment and 51 (38.9%) did not think that it was necessary. Overall, over half of the units did not audit complications of central vein cannulation.