LABORATORY PERFORMANCE OF A YIELD MONITOR

Selçuk Arslan, T. S. Colvin

Applied Engineering in Agriculture · 1999 · 22 citations · 5 references

Concepts

Abstract

Response of a yield sensor to known grain flow variations was investigated under laboratory operatingconditions through comparison with an electronic scale mounted on a test stand. The yield sensor had a quick response tosudden changes in corn flow. Based on total weight comparisons, the average percent error at constant flow rates was2.1%. The error increased to 3.2% and 4.3% when step inputs and transients were applied, respectively. The overallaccuracy was within the accuracy range (4%) reported by the manufacturer while the maximum error was more than5%. The flow rate range used in the calibration was the most important factor in achieving high accuracy. Because of thefluctuations in estimated flow rate, a single data point did not correlate well with the actual grain flow rate. Averagingover 4 to 6 s usually resulted in an error less than 4%. When the flow rate varied more profoundly during steps andtransients, approximately 10 s averaging was needed to maintain the accuracy in some of the tests. The effects of potentialsources of errors (such as varying combine ground speed, changing crop conditions, and varying grain flow profile) alsoneed to be considered to use the results of this study for field applications.