Radiology · 1999 · 49 citations · 17 references
MedicineNephrologyRadiologyDiagnostic ImagingDiagnostic RadiologyUltrasonographyContrast AgentsContrast-enhanced UltrasonographyContrast-enhanced UltrasoundRenal DiseaseRenal Function TestsRenal ImpairmentChronic Renal InsufficiencyInferior Vena Cava UltrasoundKidney Function MonitoringSerum Creatinine Assessment
The authors reviewed results of digital subtraction vena cavography with a gadolinium-based contrast agent in 14 patients with serum creatinine levels greater than or equal to 1.5 mg/dL (133 mumol/L). All cavograms were diagnostic. In 11 patients, there was no impairment of renal function. In three patients, a rise in serum creatinine level of greater than or equal to 0.5 mg/dL (44 mumol/L) was attributable to concurrent medical problems. Gadolinium-based contrast agents may be suitable for digital subtraction vena cavography in patients with renal insufficiency.
17
Azotemia: gadopentetate dimeglumine as contrast agent at digital subtraction angiography.
W. Jean Matchett, David R. McFarland, Donna Russell et al. · Radiology · 1996 · 138 citations
Medicine, Cardiology, Radiology +16