Journal of Clinical Ultrasound · 1994 · 26 citations · 17 references
Veterinary MedicineRadiologyDiagnostic ImagingUltrasonographyUltrasoundDiagnostic UltrasonographyDoppler UltrasonographyDoppler UltrasoundNeck UltrasonographyVascular UltrasonographyVascular UltrasoundBlood FlowDoppler Blood Flow AssessmentHeart RateJugular Vein UltrasonographyJugular VeinsVascular Flow Velocity MeasurementVenous Doppler EvaluationVenous Ultrasound
Doppler ultrasonography was used to examine 198 neck-vein systems (67 right, 131 left) in 148 patients. The vessel lumen is usually echo-free: the veins are supple, and the internal jugular and sometimes the subclavian veins can be compressed. The venous confluence is Y-shaped. Blood flow was symmetrical and biphasic in 57% of cases, continuous in 29% of cases, and monophasic in 13% of cases. Blood flow velocity was less than 1 m/s in all cases and varied with respiration and heart rate. Color Doppler allows flow imaging and increases the speed and reliability of the procedure. This investigation is useful for following-up patients with indwelling venous catheters and is the investigation of choice whenever pathology of the neck veins is suspected.
17
Ultrasound Guidance Improves the Success Rate of Internal Jugular Vein Cannulation
Douglas L. Mallory, William T. McGee, T H Shawker et al. · CHEST Journal · 1990 · 265 citations
Medicine, Surgery, Ultrasonography +13
Subclavian vein thrombosis: a frequent complication of subclavian vein cannulation for hemodialysis.
Jean‐Louis Vanherweghem, T. Yassine, Michel Goldman et al. · PubMed · 1986 · 130 citations