1993 · 130 citations · 6 references
EngineeringCivil EngineeringGeotechnical EngineeringMechanical Behavior Of MaterialsRock MechanicsCement IntegrityConcrete MaterialsCasing Pressure TestingCementing TechnologyDifferential Pressure TestingGas FlowGas Flow DistributionInternal PressurePressure Effects On CementingSet Cement Mechanical Properties
The study used near full‑scale laboratory tests on a common tail cement, performing rock‑mechanics stress‑strain measurements and simulating casing‑cement‑formation loading with varying internal casing pressure to assess downhole behavior. Laboratory tests on cement zone isolation revealed that cyclic application and bleed‑off of casing differential pressure exceeding 5000 psi increased gas flow through the annulus.
Abstract This paper reports results of laboratory tests on structural behavior of cement as related to zone isolation. For a commonly used tail cement, rock mechanics type tests were obtained to get detailed stress-strain behavior. Near full scale laboratory equipment was used in two tests to simulate casing-cement-formation loading and behavior downhole. The internal casing pressure was increased in one test, decreased in the other. For the casing-cement-formation combination tested, both tests showed increased gas flow through the annulus after cyclic application and bleed off of casing differential pressure greater than 5000 psi.
6