EngineeringMechatronics EngineeringElectric MachinesMachine DesignMotor DevelopmentElectric MotorsElectromagnetic Torque ProductionInduction MachinesMachine WindingsMotor Starting MethodsThree-phase MachinesInduction Motor Starting TorqueInduction MotorsStarting Method ComparisonStarting TorqueThree-phase Induction MachinesThree-phase Induction MotorsTorsional DynamicsWound-rotor Induction Motors
This paper presents a comparative study on the starting performance of three phase wound-rotor induction motors under different methods of starting. These methods are online direct starting, variable rotor resistance starting and double feed starting. In the double feed starting, the rotor winding is connected in parallel with the stator winding across the supply for a predetermined short period. By this connection, the motor produces an extremely high starting torque. For carrying out the investigations sought, a rigorous state space mathematical model has been developed and simulated. The effect of torsional dynamics has been taken into considerations.