Clinical Chemistry and Laboratory Medicine (CCLM) · 2015 · 33 citations · 10 references
EngineeringMeasurementAnalytical QualityQuality Management SystemsQuality EvaluationEmpower ProjectMedical InstrumentationSystems EngineeringApplied MeasurementBiostatisticsLaboratory ManagementTest ComparabilityClinical ChemistryLaboratory MedicineAssessmentNew WayStatisticsIntrinsic Analytical QualityReliabilityTest DevelopmentTesting TechniqueQuality AssurancePatient SafetyClinical MeasurementMedicine
Abstract Manufacturers and laboratories might benefit from using a modern integrated tool for quality management/assurance. The tool should not be confounded by commutability issues and focus on the intrinsic analytical quality and comparability of assays as performed in routine laboratories. In addition, it should enable monitoring of long-term stability of performance, with the possibility to quasi “real-time” remedial action. Therefore, we developed the “Empower” project. The project comprises four pillars: (i) master comparisons with panels of frozen single-donation samples, (ii) monitoring of patient percentiles and (iii) internal quality control data, and (iv) conceptual and statistical education about analytical quality. In the pillars described here (i and ii), state-of-the-art as well as biologically derived specifications are used. In the 2014 master comparisons survey, 125 laboratories forming 8 peer groups participated. It showed not only good intrinsic analytical quality of assays but also assay biases/non-comparability. Although laboratory performance was mostly satisfactory, sometimes huge between-laboratory differences were observed. In patient percentile monitoring, currently, 100 laboratories participate with 182 devices. Particularly, laboratories with a high daily throughput and low patient population variation show a stable moving median in time with good between-instrument concordance. Shifts/drifts due to lot changes are sometimes revealed. There is evidence that outpatient medians mirror the calibration set-points shown in the master comparisons. The Empower project gives manufacturers and laboratories a realistic view on assay quality/comparability as well as stability of performance and/or the reasons for increased variation. Therefore, it is a modern tool for quality management/assurance toward improved patient care.
10
G. Schumann, R Bonora, Ferruccio Ceriotti et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2002 · 351 citations
G. Schumann, Rainer Klauke, Francesca Canalías et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2011 · 135 citations
G. Schumann, R Bonora, Ferruccio Ceriotti et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2002 · 113 citations
Commutability Limitations Influence Quality Control Results with Different Reagent Lots
WGreg Miller, Aybala Erek, Tina D. Cunningham et al. · Clinical Chemistry · 2010 · 110 citations · Full text