Intraocular pressure measurement in the conscious rat

Camilo Cabrera, Leslie A. Wagner, M. Anthony Schork, David F. Bohrand, Bruce E. Cohan

Acta Ophthalmologica Scandinavica · 1999 · 32 citations · 6 references

DOIFull text

Open access

Concepts

Abstract

PURPOSE: To develop a method for measurement of intraocular pressure in conscious, unsedated rats. METHODS. The animal was gently held with a thick fabric mitten, topical anesthetic drops were instilled and the Tono-Pen was applied to the cornea. RESULT: Measurements in a total of 51 animals did not differ significantly among four strains studied: the overall mean intraocular pressure+/-standard deviation was 13.0+/-1.2 mm Hg. Several intraocular pressure tolerance limits were calculated from this conscious rat data to provide a baseline estimate for future studies. CONCLUSIONS: This measurement method in conscious rats may contribute to making this widely used laboratory animal available for intraocular pressure research.

References