Optics Letters · 2009 · 203 citations · 11 references
EngineeringBioengineeringBiomedical EngineeringBiosensorsPhotonicsSensorsMicrofluidic BiosensorsMultiplexed BiosensingOptical BiosensingOptical BiosensorsOptical SensorsSilicon PhotonicsBovine Serum AlbuminLabel-free Optical BiosensingMach-zehnder InterferometersOptical Beam SplittersOptical DetectionOptical SplittersReal-time MonitoringWaveguide-based Biosensing
We demonstrate a silicon photonic wire waveguide biosensor array chip for the simultaneous monitoring of different molecular binding reactions. The chip is compatible with automated commercial spotting tools and contains a monolithically integrated microfluidic channel for sample delivery. Each array sensor element is a 1.8-mm-long spiral waveguide folded within a 130 microm diameter spot and is incorporated in a balanced Mach-Zehnder interferometer with a near temperature independent response. The sensors are arranged in a 400 microm spacing grid pattern and are addressed through cascaded 1x2 optical power splitters using light from a single input fiber. We demonstrate the real-time monitoring of antibody-antigen reactions using complementary and mismatched immunoglobulin G receptor-analyte pairs and bovine serum albumin. The measured level of detection for each sensor element corresponds to a surface coverage of less than 0.3 pg/mm(2).
11
Label-Free, Single-Molecule Detection with Optical Microcavities
Andrea M. Armani, Rajan P. Kulkarni, Scott E. Fraser et al. · Science · 2007 · 1.1K citations
Sensitive disk resonator photonic biosensor
Robert W. Boyd, John E. Heebner · Applied Optics · 2001 · 401 citations