Publication | Open Access
Chronic Pain after Laparoscopic Transabdominal Preperitoneal Hernia Repair: A Randomized Comparison of Light and Extralight Titanized Polypropylene Mesh
62
Citations
18
References
2010
Year
Chronic pain is not very common in patients who have had their inguinal hernias repaired with titanium-covered polypropylene mesh. Reducing the material load from 35 to 16 g/m2 seems to further improve the biocompatibility of these meshes, thus improving the clinical outcome by reducing chronic pain to a rare event. The role of staples in causing chronic pain following inguinal hernia repair may be overestimated. There was no evidence supporting the notion that the use of the 16-g/m2 titanized meshes is associated with increased recurrence rates.