Geosynthetics International · 2007 · 135 citations · 14 references
EngineeringCivil EngineeringGeotechnical EngineeringGround ImprovementSoil MechanicsGeosynthetic ReinforcementGeotechnical DesignRetaining WallsShear StrengthShear Strength Of SoilsSoil ReinforcementFailure MechanismsFailure Mechanisms Of Reinforced SoilGeosynthetic Reinforced Retaining WallsReinforced SoilReinforced Soil WallsReinforcementRetaining Wall Failure ModesSegmental Retaining Walls
The study employed finite‑element analysis, validated against three instrumented full‑scale walls, to examine reinforced soil segmental walls with varying reinforcement spacing, length, and backfill types using the φ–c reduction method to identify failure surfaces via shear strain. Results show that while the design failure surface is adequate under working loads, the actual failure plane at collapse shifts toward a direct sliding or bilinear type originating at the toe with a shallow slope for both granular and cohesive backfills.
The failure mechanisms of reinforced soil segmental walls with extensible reinforcements were studied by performing a numerical analysis using the finite element method. The numerical approach was first verified against the results of three instrumented full-scale structures reported in the literature. Finite element models with different combinations of reinforcement spacing, reinforcement length and backfill soil were analysed. The ϕ–c reduction method, which is a special shear strength parameter reduction technique, was applied to simulate the failure conditions. The results of ϕ–c reduction analysis were used to evaluate assumptions used in current design procedures for geosynthetic-reinforced soil walls. In particular, shear strains were used to identify failure surfaces. Interpretation of the results indicated that, for both granular and cohesive backfills, the potential failure surface gradually shifts to a direct sliding mode as the system approaches failure. As a result, under working loads the potential failure surface used in current design analysis is correct, but the failure plane of a geosynthetic-reinforced soil-retaining wall at failure approaches a direct sliding type or a bilinear plane, which starts from the toe of the wall with a very shallow slope.
14
Soil Compressibility as Determined by Oedometer and Triaxial Tests