Ear and Hearing · 2006 · 19 citations · 26 references
Health ProfessionsAudiologyNeuroscienceHearing ScienceNeonatal HealthNeonatologyAuditory NeurophysiologyHearing ImpairmentHearing LossNoisePediatric Diagnostic AudiologyPediatric Hearing AssessmentAmplitude Modulation Following ResponseCarrier FrequenciesClick-evoked Auditory ResponsesClick-evoked ResponsesHearing Assessment In NeonatesInfant Auditory ScreeningInfant Hearing ScreeningStimulus Parameters
In Brief Objective: The goal was to identify stimulus features that enhance the detection of the amplitude modulation following response (AMFR) in neonates. The features explored were (1) envelope type, sinusoidal versus a half-wave rectified sinusoid (transposed); (2) best modulation frequency; and (3) spectral content, i.e., tone versus band-pass noise. Design: Results are based on recordings from 149 babies (80 babies in the neonatal intensive care unit and 69 newborn infants). All had passed hearing screening based on the click-evoked ABR. Babies were not sedated. We used carrier frequencies of approximately 500, 1000, 2000, and 4000 Hz and modulation frequencies between ∼25 and 98 Hz. For the noise stimuli, we used band-pass noise at center frequencies of 500, 1000, 2000, and 4000 Hz. All stimuli were presented through insert earphones delivered simultaneously to both ears, at intensities ranging from 20 to70 dB SPL. Magnitude squared coherence, phase coherence, and spectral criteria were used to detect criterion AMFRs. We analyzed four measures: (1) percent of satisfied runs; (2) the amplitude of criterion AMFR; (3) time to detect a criterion AMFR; and (4) response strength (e.g., the value of the magnitude squared coherence when it reached criterion minus the critical value it had to exceed for that number of averages all divided by the critical value). Results: (1) The AMFRs evoked by transposed tones were larger and detected faster than those to sinusoidal amplitude modulated tones. Consequently, remaining protocols all used the transposed envelopes. (2) The range of effective modulation frequencies was broad (41 to 88 Hz) across carrier frequencies. (3) The AMFRs evoked by transposed noise were faster and more efficient than those to transposed tones. Conclusions: In neonates, transposed tones are more effective than sinusoidal amplitude modulated tones in evoking the AMFR, modulation frequencies between 41 to 88 Hz are almost equally effective in evoking the AMFR, and band-pass noises are more effective in evoking the AMFR than tones. These three stimulus factors all add incrementally to the efficiency of evoking the AMFR. The short detection times indicate that the AMFR could be an effective tool for hearing screening. The amplitude modulation following response (AMFR, a.k.a ASSR) is a promising tool for assessing hearing on a frequency-by-frequency basis. Here we report procedures that serve to enhance the detection of this scalp potential in neonates. Scalp recordings were made between the forehead and linked mastoids in full term and premature babies (n 149) that were usually asleep. The presence of the AMFR was based on the magnitude squared coherence algorithm. Using tonal carriers we assessed the effect of envelope shape on the AMFR. Specifically, we compared a sinusoidal envelope with a transposed (i.e., half-wave rectified) envelope. The transposed envelopes evoked AMFRs that were detected faster than those to the sinusoidal envelope. Then, using the transposed envelope, we found that the time to detect the AMFR was similar for a broad range of modulation frequencies (~40 to 90 Hz). Next, using bandpass noise as a carrier, we found that these transposed, noise stimuli evoked larger and faster AMFRs than those to transposed tones. We conclude that the AMFR can be efficiently evoked over a wide range of modulation frequencies. Moreover, the use of transposed envelopes and band pass noise serve to increase the efficiency of detecting the AMFR.
26
Frequency-Specific Audiometry Using Steady-State Responses
Otávio Gomes Lins, Terence W. Picton, Brigitte L. Boucher et al. · Ear and Hearing · 1996 · 335 citations