Plasma Science and Technology · 2005 · 21 citations · 2 references
EngineeringNuclear EngineeringFusion EngineeringNuclear InstrumentationNuclear PhysicsNeutron DetectionNuclear FissionNuclear FusionRadiation Monitoring SystemsReactor InstrumentationTokamak EngineeringFission Chamber DetectorsNeutron DetectorsNeutron DiagnosticsNeutron FluxNeutron Flux MeasurementNeutron Flux MonitoringNeutron MonitoringNeutron Noise Monitoring
The prototype neutron flux monitor consists of a high purity 235U fission chamber detector and a "blank" detector, which is a fissile material free detector with the same dimension as the fission chamber detector to identify noise issues such as noise coming from gamma rays. The main parameters of the fission chamber assembly that have been measured in the laboratory are confirmed to approach the technological level of the International Thermonuclear Experimental Reactor (ITER) in the near future. This prototype neutron flux monitor will be further developed to become a neutron flux monitor suitable for the operation phase of D-D fusion on the ITER.
2