Determining Optimal Waste Volume From an Intravenous Catheter

Rachel Baker, Suzanne Summer, Michelle Lawrence, Amy Shova, Catherine A. McGraw, Jane Khoury

Journal of Infusion Nursing · 2013 · 23 citations · 13 references

DOIFull text

Open access

Concepts

Abstract

Waste is blood drawn from an intravenous (IV) catheter to remove saline or heparin before obtaining a blood sample. This study examines the minimum waste volume resulting in an undiluted sample. A repeated-measures design was used. Investigators placed an IV catheter in 60 healthy adults and obtained samples at baseline and following waste volumes ranging from 0.5 to 3 mL. A random effects mixed model was used to determine the stabilizing point, which was 1 mL of waste. Knowing that only 1 mL of waste is needed will prevent clinicians from obtaining extra waste and discarding blood needlessly.

References

13