High Temperature · 2010 · 12 citations · 4 references
EngineeringMechanical EngineeringHeat TransferHvac SystemsThermodynamicsCooling SystemsHeat Transfer AnalysisHeat Transfer FundamentalsHeat Transfer ModelingThermal DesignThermal ManagementCooling System DesignHeat Pipe CoolingHeat Pipe TechnologyHeat PipesHeat Transfer In Pipes
Results are given of development and investigations of a compact cooler for application in electronics, based on an open-loop oscillating heat pipe. The cooler operation is investigated, where water, methanol, and R141b Freon are used as working fluids under conditions of uniform and concentrated heat input. The effective operation of the device is demonstrated in the heat load range from 5 to 250 W. The “heat source-ambient air” minimal thermal resistance of 0.35°C/W was reached with water under uniform heat load of 250 W. The maximal value of heat load density is 75 W/cm2 with the heat flux concentration on the surface of 1 cm2, where methanol is used as working fluid.
4
Yury F. Maydanik · Applied Thermal Engineering · 2004 · 807 citations
H. Akachi · Medical Entomology and Zoology · 1996 · 179 citations