Ozone Science and Engineering · 2007 · 12 citations · 46 references
EngineeringChemical EngineeringEnvironmental EngineeringFluid DynamicsTransport PhenomenaWastewater TreatmentAtmospheric Oxidation ProcessesBubble DynamicsBubbly FlowGas TransferGas-liquid FlowOzone PollutionGas - Liquid Mass TransferGas Hold-upInterfacial AreaInterfacial Area ConcentrationVolumetric Mass Transfer Coefficient
Abstract A transient back flow cell model was used to model the hydrodynamic behaviour of an impinging-jet ozone bubble column. A steady-state back flow cell model was developed to analyze the dissolved ozone concentration profiles measured in the bubble column. The column-average overall mass transfer coefficient, kLa (s−1), was found to be dependent on the superficial gas and liquid velocities, uG (m.s−1) and uL (m.s−1), respectively, as follows: kLa = 55.58 · uG 1.26· uL 0.08 . The specific interfacial area, a (m−1), was determined as a = 3.61 × 103 · uG 0.902 · uL −0.038 by measuring the gas hold-up (ε G = 4.67 · uG 1.11 · uL −0.05 ) and Sauter mean diameter, dS (mm), of the bubbles (dS = 7.78 · uG 0.207 · uL − 0.008 ). The local mass transfer coefficient, kL (m.s−1), was then determined to be: kL = 15.40 · uG 0.354 · uL 0.118 . Keywords: OzoneHydrodynamicsImpinging-Jet Bubble ColumnBackmixingBack Flow Cell ModelGas Hold-upBubble CharacteristicsSpecific Bubble Interfacial AreaOverall Mass Transfer Coefficient Notes Zhou, H., "Investigation of Ozone Disinfection Kinetics and Contactor Performance Modelling", Ph.D., University of Alberta, Edmonton, Alberta, Canada., (1995)
46
P.V. Danckwerts, Arvo Lannus · Journal of The Electrochemical Society · 1970 · 2K citations
INTERNATIONAL CHEMICAL ENGINEERING
AIAA Journal · 1963 · 434 citations