Impinging-Jet Ozone Bubble Column Modeling: Hydrodynamics, Gas Hold-up, Bubble Characteristics, and Ozone Mass Transfer

Mahad Baawain, Mohamed Gamal El‐Din, Katie Clarke, Daniel Smith

Ozone Science and Engineering · 2007 · 12 citations · 46 references

Concepts

Abstract

Abstract A transient back flow cell model was used to model the hydrodynamic behaviour of an impinging-jet ozone bubble column. A steady-state back flow cell model was developed to analyze the dissolved ozone concentration profiles measured in the bubble column. The column-average overall mass transfer coefficient, kLa (s−1), was found to be dependent on the superficial gas and liquid velocities, uG (m.s−1) and uL (m.s−1), respectively, as follows: kLa = 55.58 · uG 1.26· uL 0.08 . The specific interfacial area, a (m−1), was determined as a = 3.61 × 103 · uG 0.902 · uL −0.038 by measuring the gas hold-up (ε G = 4.67 · uG 1.11 · uL −0.05 ) and Sauter mean diameter, dS (mm), of the bubbles (dS = 7.78 · uG 0.207 · uL − 0.008 ). The local mass transfer coefficient, kL (m.s−1), was then determined to be: kL = 15.40 · uG 0.354 · uL 0.118 . Keywords: OzoneHydrodynamicsImpinging-Jet Bubble ColumnBackmixingBack Flow Cell ModelGas Hold-upBubble CharacteristicsSpecific Bubble Interfacial AreaOverall Mass Transfer Coefficient Notes Zhou, H., "Investigation of Ozone Disinfection Kinetics and Contactor Performance Modelling", Ph.D., University of Alberta, Edmonton, Alberta, Canada., (1995)

References

46