Hard x-ray polarimeter utilizing Compton scattering

Hirohisa Sakurai, Motosaku Noma, Hachiro Niizeki

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 1991 · 15 citations · 0 references

Concepts

Abstract

A prototype polarimeter with a 50 mm diameter has been constructed. With polarized x-rays from a simple polarizer, the detection efficiency and modulation factor of the polarimeter with a 40 mm thick scatterer were 3.2% and 0.57%, respectively, at 60 keV. The fabrication and performance of the polarimeter and polarizer are presented.