Toxicological Data after Heroin Overdose

Pascal Kintz, Patrice Mangin, A. Lugnier, A. J. Chaumont

Human Toxicology · 1989 · 43 citations · 9 references

Abstract

Capillary gas chromatography with selective nitrogen detection was employed to quantify morphine and 6-monoacetylmorphine in biological fluids and tissues in five deaths attributed to heroin injection overdose. The minimum lethal concentration found was 0.021 micrograms morphine per ml of blood. In all cases, 6-monoacetylmorphine was identified in urine, confirming heroin abuse.

References